Ecosafe H122ZPlus filterkast 120 cm breed zonder filters
Art.Nr.
L201H122Z+

Ecosafe H122ZPlus filterkast 120 cm breed zonder filters

Art.Nr.
L201H122Z+
Ecosafe H122Z + 120 cm breed met 2 filterunit
Voorkant met trapezium opening over bijna de gehele breedte
Standaard uitgerust met SF3 filteralarm
Intern (bxdxh) 1145 x 700 x 935 cm
Gewicht circa 85 kg
Levering zonder filters en werkblad
De gebruiker is verantwoordelijk voor regelmatige controle van de filters en minimaal 1 x per jaar wordt vervanging geadviseerd
Bekijk alle specificaties
excl. BTW  4.510,-
4 855,-
(Alle prijzen zijn exclusief BTW)
-
+
Specificaties
Specificaties
Merk Ecosafe
Afscheider zuigzijde Nee
Condenser uitlaat Nee
Productbeschrijving

Ecosafe h222Z filterkast 120 cm breed zonder filters

  • Filterkast h222D, 120 cm breed met 2 filterunit
  • Voorkant met trapezium opening over bijna de gehele breedte
  • Standaard uitgerust met SF3 filteralarm
  • Intern (bxdxh) 1145 x 700 x 935 cm
  • Gewicht circa 85 kg
  • Levering zonder filters en werkbald

De gebruiker is verantwoordelijk voor regelmatige controle van de filters en minimaal 1 x per jaar wordt vervanging geadviseerd

 

Ductless fume hoods Labopur® Nf X 15-211 - May 2009 - class 2

Why using an enclosure with recirculating air filtration system?

When using chemicals, your health might be in danger due to the emanation of harmful and toxic vapours. To protect yourself and your close environment, you must manipulate your products in an enclosure using recirculating air filtration (formely Enclosure for Toxics using Recirculating Air Filtration or ETRAF) equipped with a molecular filter.

Why choosing an enclosure LABOPUR® using recirculating air filtration?

Following its wide experience with safety cabinets and storage of dangerous products, ECOSAFE-leading manufacturer of safety cabinets-uses its entire technical knowledge to design and manufacture its fume hoods LABOPUR®. Made in EU, the fume hoods LABOPUR® stand out by a high manufacturing quality and finition. The entire process being controlled with the European standard ISO 9001 -2000.

Fume hoods LABOPUR® provide the user a secured work space for the repetitive manipulations of small chemicals quantities. The dangerous vapours are confined in the enclosure, then are cleansed while entering the active coal-based filter. Finally, dangerous vapours are rejected in the atmosphere without danger for the environment. Thus, the user's health is protected.

The LABOPUR® filter system is made of quality active charcoal according to your needs. It can be fit for a specific product. The active coal-based filters replacement requires only a few minutes.

Fume hoods LABOPUR® also allow you to save energy. Indeed, compared with enclosures with outside rejections, it is not necessary to heat or cool the incoming air. Furthermore the air in the room is cleaned.

Standartization:

NF X 15-211 French norm (September 1996):

NF X 15-211 French norm is the most demanding regulation today. It garantees to the user a full safety allowing him to focus on his manipulations.

Enclosures for toxic LABOPUR® using recirculating air filtration are classified according to 2 security levels:

- class 1 : enclosure with safety reserve
- class 2 : enclosure without safety reserve, the most common

Enclosures LABOPUR® using recirculating air filtration belongs to the class 2.

To be in accordance with this standard, fume hoods filtration LABOPUR have to meet multiple criteria (summary):

- the enclosure must be provided with a ventillation device to maintain the air speed with a rate between 0,4 m/s and 0,6 m/s.
- rejection, dowstream the filter, of 50% of the VME (mean value of exhibition) of toxics treated in the enclosure in the duration of normal filter use.
- the enclosure must have been tested by an approved and independent laboratory.
- the class 2 enclosures have to allow to treat products having a VME index superior or equal to 10 ppm.
- the class 2 enclosures have to be equipped with a sound or visual alarm activated every working 60 hours and also a sampling outlet device.
- the class 2 enclosures must not reject more than 50% of the VME downstream the filter during the detection test.

Certification :

Fume hoods LABOPUR® were approved according to the NF X 15-211 standard, by a independant laboratory, MAPE, itself approved by the COFRAQ. The COFRAQ accreditation gives evidence of the technical skills of the test laboratory by the highest european certification organisation.

LABOPUR® fume hoods are controlled according to quality process and procedures defined by the repository of international quality standard ISO 9001-2000, at the end of the assembly line and before their shipping to the user in order to assure a perfect functioning and efficiency.