- Groot assortiment A-merken
- Vakkundig advies
- Online offerte functie
- Advies via videobellen
- Gratis bezorging vanaf 250,- excl. BTW in NL
Met actieve vochtregeling, rH van 20 tot 95% en uitschakelbaar
Temperatuurbereik: 7 graden boven kamertemperatuur tot 90°C
Met TwinDISPLAY bediening & AtmoControl software
Verwarmde glazen binnendeur
Inclusief 2 inlegbladen (max. 10 mogelijk)
Afmeting intern (bxdxh) 560 x 400 x 700 mm
Gewicht circa 120 kg
Wordt geleverd met 2,5 l jerrycan voor demimater (zonder water)
Merk | Memmert |
---|---|
Licht | Nee |
Volume | 156 liter |
Min. Temperatuur | 30 |
Max. Temperatuur | 90 |
Memmert HCP150 klimaatkast KT-90°C 20-95%rH 156 liter
This climate chamber offers the full range of comfort, reliability and safety. Thanks to active humidity control from 20 % to 95 % rh and unsurpassed homogeneity of temperature and humidity over the entire interior, it is ideally suited for environmental testing, environmental simulation, accelerated service life tests, corrosion tests and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.
- Temperature range up to +90 °C
- Active humidity control 20 to 95 % rh
- Double doors as standard: Prevention of contamination and drops or rises in temperature, and at the same time an optimal view of the sensitive chamber load through wide-area heated inner glass door
Humid environment without condensation
The active humidity control ensures an ideal homogeneity of temperature and humidity as well as short recovery times after opening the door in this attractively priced and practically maintenance-free climate chamber. In combination with heating on all six sides, including heated inner glass door, it also minimises vaporisation in the interior and thus the risk of condensed water dripping onto the test object. An aluminium thermal conductive layer supports optimum temperature distribution and serves as a heat accumulator in case of a temporary power failure.
Comfortable equipment for accelerated service life tests
To ensure that environmental tests and accelerated life tests such as HALT tests and 85/85 tests run reliably and safely, the humidity chamber HCP offers a wide range of comfort functions: Standard feed-through on the rear panel, battery-buffered ControlCOCKPIT (option), process runtime starts with SetpointWAIT function only when the setpoint temperature is reached, alarm messages can be sent via e-mail or SMS with MobileALERT (option) and much more.
Temperature Humidity Working Range HCP
Not all climate chambers are the same. The humidity content of the chamber load, the ambient conditions and the respective temperature-humidity working range are decisive factors in the selection of the right appliance. In the adjacent diagram, you can see the possible temperature/humidity combinations for our humidity chambers HCP.
Within the respective temperature-humidity range, permanent operation is possible (at an ambient temperature of 22 °C ± 3 K, relative humidity < 50 %). Condensation may occur in the threshold range. To which extent depends on the humidity content of the chamber load and the ambient conditions.
Technical data
Temperature
Working-temperature range | above ambient temperature up to +90 °C |
---|---|
Setting temperature range | +18 to +90 °C |
Setting accuracy temperature | 0.1 °C |
Temperature | 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error |
Humidity
Humidity Control | Active microprocessor control for humidifying and dehumidifying (20 - 95 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam, dehumidifying via sterile filter |
---|---|
Setting range active humidity control | 20 to 95 % rh and rh-Off |
Setting accuracy humidity | 0.5 % rh |
Control technology
ControlCOCKPIT | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. |
---|---|
Language setting | German, English, Spanish, French, Polish, Czech, Hungarian |
adjustable parameters | temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime |
Timer | Digital backwards counter with target time setting, adjustable from 1 minute to 99 days |
Function SetpointWAIT | the process time does not start until the set temperature is reached |
Calibration | three freely selectable values each, temperature and humidity |
Communication
Interface | Ethernet LAN, USB |
---|---|
Documentation | programme stored in case of power failure |
Programming | AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
Safety
AutoSAFETY | additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature |
---|---|
Autodiagnostic system | integral fault diagnostics for temperature and humidity control |
Alarm | visual and acoustic |
Heating concept
6 sides | large-area multi-function heating system on four sides with additional door and back heating to avoid condensation |
---|
Standard equipment
Works calibration certificate | Works calibration certificate (measuring point chamber centre) at 60 °C with 75 % rh |
---|---|
Entry port | Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back, centre left |
Door | Additional heated inner glass door |
Door | fully insulated stainless steel door with 2-point locking (compression door lock) |
Internals | 2 perforated stainless steel shelf/shelves |
Stainless steel interior
Interior | material 1.4301 (ASTM 304), corrosion resistant |
---|---|
Volume | 156 l |
Dimensions | w(A) x h(B) x d(C): 560 x 700 x 400 mm |
Max. number of internals | 10 |
Max. loading of chamber | 120 kg |
Max. loading per internal | 15 kg |
Textured stainless steel casing
Dimensions | w(D) x h(E) x d(F): 719 x 1070 x 591 mm |
---|
Electrical data
Voltage Electrical load | 230 V, 50/60 Hz approx. 1800 W |
---|---|
Voltage Electrical load | 115 V, 50/60 Hz approx. 1800 W |
Ambient conditions
Ambient temperature | 10 °C to 30 °C |
---|---|
Set Up | The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm. |
Humidity rh | max. 70 %, non-condensing |
Altitude of installation | max. 2,000 m above sea level |
Overvoltage category | II |
Pollution degree | 2 |
Packing/shipping data
Transport information | The appliances must be transported upright |
---|---|
Customs tariff number | 8419 8998 |
Country of origin | Federal Republic of Germany |
WEEE-Reg.-No. | DE 66812464 |
Dimensions approx incl. carton | w x h x d: 800 x 1250 x 800 mm |
Net weight | approx. 90 kg |
Gross weight carton | approx. 116 kg |