IKA LR-2.ST Compact power labreactor
Art.Nr.
L030013294
Pakket bestaande uit:
Statiefset met reactordeksel, veilighiedsschakelaar, bovenroerder Eurostar 60 control
Volume 500 - 2000 ml, viscositeit tot 50.000 mPAs
Toerental 8 - 290 rpm
Materiaal in contact met medium: Borosilikatglas, FFPM, PTFE, Stahl 1.4571
Mogelijk vacuüm 25 mbar
Afmetingen (bxdxh) 460 x 430 x 1240 mm
Gewicht 25 kg
Levering zonder reactorvat, water/oliebad en andere hierboven niet vermelde toebehoren
Installatiekosten op aanvraag
Statiefset met reactordeksel, veilighiedsschakelaar, bovenroerder Eurostar 60 control
Volume 500 - 2000 ml, viscositeit tot 50.000 mPAs
Toerental 8 - 290 rpm
Materiaal in contact met medium: Borosilikatglas, FFPM, PTFE, Stahl 1.4571
Mogelijk vacuüm 25 mbar
Afmetingen (bxdxh) 460 x 430 x 1240 mm
Gewicht 25 kg
Levering zonder reactorvat, water/oliebad en andere hierboven niet vermelde toebehoren
Installatiekosten op aanvraag
Sorry, dit product kunt u niet toevoegen aan uw winkelwagen.
Merk | IKA |
---|---|
Afscheider zuigzijde | Nee |
Condenser uitlaat | Nee |
IKA LR-2.ST Compact power labreactor
Modularly configured laboratory reactor for the optimization and reproduction of various chemical reactions, mixing and homogenization processes on a lab scale.
The system is particularly characterized by the agitator mounting, which allows for a safe transfer of the higher motor torque.
ULTRA-TURRAX® dispersers, temperature sensors, flow breakers and other accessories can be attached to the open ports of the reactor cover.
- Suitable for vacuum operation
- Solvent- and temperature-resistant perfluoroelastomer (FFPM) seals come into contact with sample
- Infinitely variable speed
- Torque trend display for measuring changes in viscosity
- Microprocessor-controlled speed regulation, enables steady speed, also under load
- Removable WiCo (wiresless controller) for remote and safe use in a fume hood
The LR-2.ST laboratory reactor system consists of:
- Stand system
- EUROSTAR 60 control laboratory stirrer with higher speed and no gear ranges
- Safety switch
- Reactor cover
Technical data
- Telescope stand stroke : 390mm
- Usable volume min.: 500ml
- Usable volume max.: 2000ml
- Width: 460mm
- Depth: 430mm
- Viscosity max.: 50000mPas
- Weight: 25kg
- Height: 1240mm
- Working temperature max. : 230°C
- Working temperature min. : Room temp.°C
- Permissible ambient temperature max.: 40°C
- Permissible ambient temperature min.: 5°C
- Reactor vessel openings (units/standard): 3/NS 29/32 2/NS 14/23
- Permissible relative humidity: 80%
- Attainable vacuum: 25mbar
- Speed min.: 8rpm
- Speed max.: 290rpm
- Material in contact with medium: borosilicate glass, FFPM, PTFE, steel 1.4571